Mediana
AED Mediana HeartOn A15 Adult and Paediatric Defibrillator
- SKU:
- 2870
- UPC:
- 0644221804315
- MPN:
- 2870
- Weight:
- 4.20 KGS
Description
• Instant switch from Adult to Paediatric
• Automatic switch on when lid opened
• Pads attached, ready for use
• Pads fit both Adults and Paediatrics
Facts:
- Four times as many women die as a result of a heart attack than they do from breast cancer.
- In the UK, twelve people under the age of 35 die every week due to sudden cardiac arrest.
- For every minutes delay, a victim's chance of surviving a sudden cardiac arrest drops by 7-10%.
- 70% of cardiac arrests occur outside of a hospital environment.
- Almost 95% of sudden cardiac arrest victims die before reaching hospital.
- CPR effectively administered immediately after sudden cardiac arrest, can double a victim's chance of survival.
- Seven out of ten cardiac arrests occur outside of hospital. Currently in the UK, only 2-3% of these people survive.
- Around 270,000 people suffer a heart attack in the UK each year. Of these, up to a third will die before reaching hospital.
- The Department of Health has a target of placing 3,000 new defibrillators in public places in England.
- Explorer, Sir Ranulph Fiennes, is alive today largely thanks to a defibrillator located at Bristol airport.
- Passive smoking increases the risk of developing coronary heart disease by up to 30%.
- Early defibrillation can triple a victims chance of survival.
PRODUCT SPECIFICATION:
DEFIBRILLATION ELECTRIC SHOCK
Waveform:
Biphasic Truncated Exponential (BTE)
waveform (Impedance compensation)
Energy:
Adult: 185 to 200J (±5%)
Paediatric: 45 to 50J (±5%)
Operating Mode: Semi-Auto
ECG
Lead: II (RA,LL)
Patient Impedance: 25 to 175ohm
Detection
V/F more than 200μV
V/T more than 160 per min
INDICATION
CONTROLS
Standard:
Open (power) switch, shock button,
Adult/Paediatric mode switch
INDICATORS
Visible: ICON Indicator, Status LCD (unit status, battery status, temperature status), LED (Adult/Paediatric mode switch LED)
Audible: Speaker (voice prompt), Beep (CPR indication)
PHYSICAL
Dimensions: 294H x 240W x 95mmD
Weight: Approx. 2.65kg (including battery, excluding pads)
SELF TEST
Cycle:
Every 24 hours, 1 week, 1 month
Power on self test, battery insertion self test
Test Result: Status LCD displays ‘O’ / ‘X’
DATA BACKUP AND COMMUNICATION
Standard SD card, IR communication port
ACCESSORY SPECIFICATION
Standby Life: 2 years from date of manufacture
Electrodes: Disposable pads
Placement:
Adult: Anterior-lateral
Paediatric: Anterior-posterior
Minimum active gel area: 80cm2 +/-5%
Cable Length: Approx. 1.8m
Environmental Conditions
Temperature:
Operation: 0 to 43°C (32 to 109.4°F)
Storage: 0 to 43°C (32 to 109.4°F)
Relative Humidity: 5 to 95% RH (non-condensing)
BATTERY
Type: LiMnO2, disposable, long-life primary cell
Voltage/Capacity: 15V, 4200 mAh
Shelf Life: 2 years from date of manufacture (in the original packaging)
Standby Life: 5 years from date of manufacture (inserted in the AED)
Discharge: A minimum of 200 shocks (except the CPR period between the defibrillation therapy) or 10 hours of operating time at 20°C
Environmental Conditions
Temperature:
Operation: 0 to 43°C (32 to 109.4°F)
Storage: 0 to 43°C (32 to 109.4°F)
Relative Humidity: 5 to 95% RH (non-condensing)
Information correct at time of going to press. Subject to change without notice.